4.2  Search recommendations and hints for Reset operation 

During the search process be sure that you do not

 

carry items of metal with you. This 

could cause a wrong adjustment when pressing the 

Reset

 key and can produce false 

indicator  effects.  Furthermore  this  can  lead  to  a  wrong  metal  discrimination.  While 
searching  be  ensured,  that  the  sound  remains  constant,  otherwise  an  inappropriate 
adjustment  caused  by  magnetic  fields  may  occur.  Should  this  be  the  case  press 
Reset-button again and adjust frequency once more. Hold searchcoil over the ground 
and control display. 
 
The Reset-button should be pressed after each of the following modifications: 
 
1.  After every switch-on of the metal detector. 
2.  After every exchange of searchcoils. 
3.  During  the  search,  if  sound  becomes  instable  due  to  bad  soil  conditions  or 

geomagnetism. 

 
During  search  and  in  particular  before  excavation  of  the  object  the  following  factors 
should be taken into account in order to make the search more targeted and thus more 
successful. 
 
1.  Change of sound (frequency) 
2.  Intensity of sound 
3.  Continuity of sound 
4.  Extent of value (digital display) 
 
The change of sound is the first sign for the finding of a metal object. At the same time 
there  should  other  circumstances  be  considered  and  the  own  search  experience  be 
used as support: 
 
The more intense the sound, the larger the metal object and the nearer it is located to 
the surface. While a high search tone is audible, it is required to move the searchcoil in 
the close surrounding to determine the shape of the metal object. 
 

ID (metal discrimination): 

 
Unlike to other metal detectors GOLD ID-XL performs a constant metal discrimination. 
Conductivity value and metal type (e.g. “Gold”) are displayed. 

Summary of Contents for GOLD ID-XL

Page 1: ...GOLD ID XL User s manual Pulse Induction based Metal Detector KTS Electronic GmbH Co KG Germany...

Page 2: ...3 2 Cylindrical coil 4 3 3 1 x 1 m PVC search frame 5 3 4 Assembly of the search frame 5 3 5 Battery and chargers 6 4 Electronic unit 6 4 1 Back 7 4 2 Search recommendations and hints for Reset opera...

Page 3: ...L and are at your disposal should additional questions arise Your KTS Electronic Team 1 2 Scope of delivery GOLD ID XL electronic unit with installed li ion battery and leather bag 25 cm 10 searchcoil...

Page 4: ...ld the searchcoil flat and parallel to the ground and determine your own search speed 3 Usage and selection of searchcoils In addition to your GOLD ID XL we deliver several searchcoils each suitable f...

Page 5: ...e sized metal pieces are not indicated 3 4 Assembly of the search frame 1 Connect the pipes 8 pieces in numerical order 2 Arrange the search frame on a flat surface and be sure that the frame is strai...

Page 6: ...bles charging in the car Note The maximum charging time is 90 minutes To avoid a defect on charger or built in battery this charging time must not be exceeded a disregard could lead to a loss of warra...

Page 7: ...after each charge The GOLD ID XL is ready for use within a very short time 1 Activate the metal detector with the ON OFF button The respective searchcoil should be cable connected to the electronic un...

Page 8: ...During the search if sound becomes instable due to bad soil conditions or geomagnetism During search and in particular before excavation of the object the following factors should be taken into accou...

Page 9: ...in case of difficult soil conditions an increase in disturbances can occur which can be reduced by a renewed reset and a reduction in the frequency As long as the searchcoil is positioned exactly over...

Page 10: ...n be assumed if a high tone in any direction is heared 5 Search process Please note the following Avoid conducting overhead lines Do not use cell phone during operation Do not process measurements dur...

Page 11: ...from an object of 5 x 5 cm in dimension 4 The measured values can be falsified because other metal parts are detected near the located metal object 5 Strongly magnetic interference fields within resi...

Page 12: ...rned product cannot be repaired in an appropriate budget time frame On site repairs cannot be demanded Replaced resp exchanged parts will merge into our property The guarantee claim expires in cases o...

Page 13: ...t the monument protection as well as other legal standards are relevant KTS Electronic GmbH Co KG assumes no responsibility for possible legal violations In case of doubts we recommend a comprehensive...

Reviews: