5 INSULATION MEASUREMENT
22
310393-51
–
Measure the resistance between the specified points.
Measuring point VB
–
Measuring point Motor case
Value as per
HV Safety
» If the specified value is not reached:
–
Contact KTM customer service and send in the motor.
310394-51
–
Measure the resistance between the specified points.
Measuring point UA
–
Measuring point Motor case
Value as per
HV Safety
» If the specified value is not reached:
–
Contact KTM customer service and send in the motor.
310395-51
–
Measure the resistance between the specified points.
Measuring point UB
–
Measuring point Motor case
Value as per
HV Safety
» If the specified value is not reached:
–
Contact KTM customer service and send in the motor.