4 ZERO POTENTIAL
12
310412-51
–
Measure the voltage between the specified points.
Measuring point HV+
–
Measuring point HV
−
< 40 V
» If the specified value is not reached:
–
Discharge the intermediate circuit capacitors (motor
removed).
–
Clean the sealing surface.
Info
Sealant on the contact surface between the motor
housing and the measurement tip can falsify
measurements.
310413-51
–
Measure the voltage between the specified points.
Measuring point HV+
–
Measuring point Motor case
< 40 V
» If the specified value is not reached:
–
Discharge the intermediate circuit capacitors (motor
removed).