35
300459-10
–
Connect the filling cylinder to connector
.
Filling gas - nitrogen
–
Adjust pressure regulator
.
Guideline
Gas pressure
10 bar (145 psi)
–
Position the damper in the special tool.
The hexagonal part of tap handle
engages in the hexagon socket of the fill-
ing port screw.
–
Open spigot
.
The piston rod moves out as the damper is filled.
Info
The spigot is opened when the sleeve is pushed toward special tool
and
closed when it is pulled away from the special tool.
If nitrogen escapes, the damper must be pressed more tightly against the
seal of special tool
.
–
Fill the damper for at least 15 seconds.
Guideline
Gas pressure
10 bar (145 psi)
Info
Observe the pressure regulator dial.
Ensure that the damper is filled to the required pressure.
–
Close the screw of the filling port using tap handle
.
–
Close the spigot and take the damper out of the special tool.
–
Tighten the screw of the filling port.
Guideline
Screw, filling port
M5
3 Nm (2.2 lbf ft)
6.21
Installing the spring (50 SX Junior, 50 SX Mini)
–
Assemble the damper. (
200896-10
–
Clamp the damper into the vise using soft jaws.
–
Mount the retaining ring and turn it all the way down.
The collar faces the adjusting ring.
–
Mount the adjusting ring and turn it all the way down.
The collar faces the spring.
–
Measure the overall spring length when not under tension.
–
Mount the spring.
Guideline
Spring rate
Weight of rider: < 25 kg (< 55 lb.)
65 N/mm (371 lb/in)
Weight of rider: 25… 35 kg (55…
77 lb.)
75 N/mm (428 lb/in)
Weight of rider: > 35 kg (> 77 lb.)
85 N/mm (485 lb/in)
200895-10
–
Mount spring retainer
.
The open end is across from the spring end.