01/FORK, TRIPLE CLAMP
17
200979-01
–
Disassemble the fork legs. (
–
Disassemble the cartridge. (
–
Check the fork legs. (
–
Assemble the cartridge. (
–
Assemble the fork legs. (
5.13
Disassembling the fork legs
Info
The steps are identical for both fork legs.
Condition
The fork legs are disassembled.
200736-10
–
Remove protective cover
A
.
–
Note down the present state of rebound damping
1
and compression damping
2
.
–
Note down of the present state of the spring preload.
–
Completely open the adjusters of the rebound damping and compression damping.
201347-10
–
Clamp the fork leg in the area of lower triple clamp.
Clamping stand (T1403S) (
200737-10
–
Loosen
Preload Adjuster
3
.
Pin wrench (T103) (
Info
The
Preload Adjuster
cannot be taken off yet.