the switch will check the VLAN group setting with the VLAN ID. If
they belong to the same VLAN, the packets will be forwarded. If they
belong to different VLANs, the packets will be filtered out.
Note: Because this switch support s VLAN ID 0~15 only , the switch will
use bit 0~3 of VLAN ID as its VLAN ID if the VLAN ID in tagged
packet s are larger than 15.
6. You can use command "
m
" to set ports to tag or untagged and set PVID
of ports. T he output packets from a tag port will always be tagged
packets. If untagged packets, tag will be added before these packets are
transmitted. And the output packet s from untagged port will always be
untagged packets. If tagged packets, the tag will be removed before
these packets are transmitted.
The tag or untagged setting depends on your applications in network. If
you are not sure about your network application, you may set all of
them to un tagged because lots of old network devices do not support
long Ethernet packets with tag (tag is another 4 bytes added to normal
Ethernet packets) .
Notes
:
Data will only be forwarded to ports in the same VLAN group. Data will not be
forwarded to ports in different VLAN groups, just like they were not connected
together. The factory default setting of the switch is all ports are in the same VLAN
group.
[ 4 ]
Setup Trunking Connection of the Switch
1. Enter the Trunk setup function in the main menu as follow.
2. This switch supports two trunks and two port s per trunk maxim um.
You can select the trunk and enable or disable it in this setup function.
Notes: Before you enable the trunk, please check the VLAN setting of the ports used
for trunk. They must belong to the same VLAN group and have the same PVID and
tag/untagged s etting. If they are different on some items, please make them have
the same configuration first.
[ 5 ] Change Password
1. You can change password with this function.