2.4 Making TP Port Connection

TP port is featured to support connection to :

Auto-negotiation devices

Auto-negotiation incapable 10BASE-T devices

Auto-negotiation incapable 100BASE-TX devices

Network Cables

10BASE-T:

2-pair UTP Cat. 3,4,5 , EIA/TIA- 568 100-ohm STP

100BASE-TX:

2-pair UTP Cat. 5, EIA/TIA-568 100-ohm STP

Link distance:

Up to 100 meters

Configuration Setup

To make a proper connection, the following configuration settings are
recommended:

TP port link partner

SW1

SW2

SW3

Auto-negotiation device

Off: auto

Off: full duplex

Off:  100M

Fixed 10M half duplex device On: forced

On: half duplex

On:  10M

Fixed 100M half duplex device On: forced

On: half duplex

Off:  100M

Fixed 10M full duplex device

On: forced

Off: full duplex

On:  10M

Fixed 100M full duplex device On: forced

Off: full duplex

Off:  100M

Summary of Contents for KC-300DM series

Page 1: ...1 10 100BASE TX TO 100BASE FX MEDIA CONVERTERS KC 300DM Series Installation Guide DOC 060215 KC 300D...

Page 2: ...erves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For...

Page 3: ...may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CE NOTICE Marking by the symbol indicates compliance of this equip...

Page 4: ...e TP Port Monitoring Function 13 1 4 6 Loop Back Test Function 13 2 Installation 14 2 1 Unpacking 14 2 2 Mounting the Device 14 2 3 Applying Power 15 2 4 Making TP Port Connection 16 2 5 Making FX Por...

Page 5: ...n Support 10Mbps and 100Mbps speed on TP connections Auto MDI MDI X detection function on the TP port Auto negotiation function on the TP port Link fault pass through function Provide manual configura...

Page 6: ...tection Signal Compliance IEEE802 310BASE T 802 3u100BASE TX Data Speed 10Mbps or 100Mbps Duplex Mode Half duplex or Full duplex Configuration Auto negotiation capable and optional forced manual setti...

Page 7: ...Stop loop back test UserAccessibleSettings SW NO SETTING STATE FUNCTION SW1 TPPortConfiguration OFF Auto negotiation default ON Forcedmode SW2 TPPortDuplex OFF Fullduplex default ON Halfduplex SW3 TPP...

Page 8: ...es FXOL FX port optical link ON Optical signal is detected OFF No optical signal RTPLINK Remote TP port link ON Link up and no traffic OFF Link fault RTP100M Remote TP port speed ON 100Mbps OFF 10Mbps...

Page 9: ...E 802 1Q VLAN tagged packets Packet Length Upto1522bytesatstore and forwardmode No limit at smart forward mode 100to100 Flow Control Back pressure for half duplex mode 802 3xpause framebaseforfulldupl...

Page 10: ...SC SMF 1310nm 5 0dBm 34dBm 300DM SL6 SC SMF 1310nm 5 0dBm 35dBm 300DM SL7 SC SMF 1310nm 3 3dBm 37dBm 300DM SL9 SC SMF 1310nm 0 5dBm 37dBm 300DM SL10 SC SMF 1550nm 3 3dBm 37dBm 300DM SL12 SC SMF 1550nm...

Page 11: ...ice automatically when each time a link is being established 1 4 3 Far End Fault Function The FX port is facilitated with this function which conforms to IEEE 802 3u 100BASE FX specifications When the...

Page 12: ...the TP port will force a link down on the FX port Similarly a link fault detected on the FX port will also force a link down on the TP port As illustrated in the following figure this function allows...

Page 13: ...Function As illustrated in the following figure the local MC starts a loop back test by pressing the loop back test button It sends test frames from its FX port to the remote MC The remote MC forwards...

Page 14: ...rom and adequate ventilation around the device Do not place heavy objects on the device WallMounting The media converter also can be mounted on a wall On bottom of the device wall mounting hole is pro...

Page 15: ...your area options RatedAC120V 60HzDC7 5V1A RatedAC230V 50HzDC7 5V1A RatedAC100V 50 60HzDC7 5V1A RatedAC100V 50 60HzDC5V1A RatedAC240V 50HzDC7 5V1A Steps to apply the power to the converters are 1 Conn...

Page 16: ...TIA 568 100 ohm STP Link distance Up to 100 meters ConfigurationSetup To make a proper connection the following configuration settings are recommended TP port link partner SW1 SW2 SW3 Auto negotiation...

Page 17: ...2km 300DM SA2 SC 1310nm DuplexSMF 20km 300DM SL2 SC 1310nm DuplexSMF 20km 300DM SL3 SC 1310nm DuplexSMF 30km 300DM SL4 SC 1310nm DuplexSMF 40km 300DM SL6 SC 1310nm DuplexSMF 60km 300DM SL7 SC 1310nm D...

Page 18: ...15 20km Rx 1310nm 300DM W3540 Bi Di SC Tx 1310nm Single SMF 40km Rx 1550nm 300DM W5340 Bi Di SC Tx 1550nm Single SMF 40km Rx 1310nm Since the WDM single fiber media converters use different wavelengt...

Page 19: ...nk fault Blink Rx Tx activities FXOL FX port optical link On Optical signal is detected Off No optical signal is detected Link Fault Pass Through Function is enabled TPLINK FXLINK FXOL Interpretation...

Page 20: ...ED It is ON to indicate a complete of loop back test and OFF during test 4 Check RTP FDX LEDfor the test result It is ON to indicate a TEST PASS and OFF forTEST FAIL 5 Release Loop back test button RT...

Page 21: ...s The setting jumpers are not accessible by users generally For accessing these jumpers the upper case must be removed from the product Re moving the case must be performed by an authorized and experi...

Page 22: ...peed on both TP port and FX port Direct conversion method converts the signal between TP port and FX port without storing the received packet on one port then forwarding to another port The media conv...

Page 23: ...method uses pause frames for one port to stop further transmission from its link partner 3 1 3 FX Duplex Setting JP3 This setting is used to set the duplex mode of the FX port 3 2 JP1 JP3 Factory Def...

Reviews: