KTI Networks KPOE-100 Installation Manual Download Page 3

3

The information contained in this document is subject to change without prior notice.
Copyright (C) All Rights Reserved. 

TRADEMARKS 

Ethernet is a registered trademark of Xerox Corp.   

FCC NOTICE

This device complies with Class B Part 15 the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and (2) this 
device must accept any interference received including the interference that may cause. 

CE NOTICE

Marking by the symbol  indicates compliance of this equipment to the EMC directive of the 
European Community. Such marking is indicative that this equipment meets or exceeds the 
following technical standards: 

EMC Class B 
EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 Class B 
     EN61000-3-2:2000 
     EN61000-3-3:1995/A1:2001 
EN 55024:1998/A1:2001 
     IEC 

61000-4-2:1995 

     IEC 

61000-4-3:1995 

     IEC 

61000-4-4:1995 

     IEC 

61000-4-5:1995 

     IEC 

61000-4-6:1996 

     IEC 

61000-4-8:1993 

     IEC 

61000-4-11:1994 

SAFETY CAUTION 

To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe 
the following precautions. 

•  Do not service any product except as explained in your system documentation.   

•  Opening or removing covers may expose you to electrical shock. 

•  Only a trained service technician should service components inside these compartments. 

•  If any of the following conditions occur, unplug the product from the electrical outlet and 

replace the part or contact your trained service provider: 

 

- The power cable, extension cable, or plug is damaged. 

 

- An object has fallen into the product. 

 

- The product has been exposed to water. 

 

- The product has been dropped or damaged. 

 

- The product does not operate correctly when you follow the operating instructions. 

•  Do not push any objects into the openings of your system. Doing so can cause fire or 

electric shock by shorting out interior components. 

•  Operate the product only from the type of external power source indicated on the electrical 

ratings label. If you are not sure of the type of power source required, consult your service 
provider or local power company. 

Summary of Contents for KPOE-100

Page 1: ...1 Mid span 802 3af PoE Injector Installation Guide KPOE 100 Doc 070521 ...

Page 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...

Page 3: ... 4 11 1994 SAFETY CAUTION To reduce the risk of bodily injury electrical shock fire and damage to the product observe the following precautions Do not service any product except as explained in your system documentation Opening or removing covers may expose you to electrical shock Only a trained service technician should service components inside these compartments If any of the following conditio...

Page 4: ...located at place where no commercial outlet is available Features IEEE 802 3af PSE standard compliance Mix Ethernet signals and 48V power into one RJ 45 port Delivers 48VDC power up to 15 4W Delivers power over Cat 5 up to 100 meters Discovery of IEEE 802 3af compliant powered devices PD Auto power shutdown when no connection Auto power shutdown protection when non 802 3af PD is detected Overload ...

Page 5: ...8 Negative VPORT 48VDC Cable 4 pair Cat 5 5e Length Mid span up to 100m LAN IN cable PoE OUT cable PoE PSE Discovery resistance 15K 33K Classification Class 0 4 Power delivery 15 4W max Under voltage protection VPORT 43V Over voltage protection 53V VPORT Over current detection 350 mA IPORT 400 mA for 75ms Maximum current limit 400 mA IPORT 450 mA for 75ms Under current detection 7 5mA for 300 400m...

Page 6: ... IN Jack Connector Power Jack Input voltage 48VDC supplied by external power adapter Input current DC 0 4A min Environment Temperature Operating 5 50o C Storage 20 85 o C Relative humidity 5 95 non condensing Mechanical Housing Plastic Mounting Wall mounting screw support ...

Page 7: ...100 240VAC Rated frequencies 50 60Hz Input voltage range 90 264VAC Input frequency range 47 63Hz Input AC plug IEC320 C14 plug 3 pin Output voltage 48VDC 5 Output current DC 0 5A max Max output power 24W Consumption at no load 0 5W max Output DC plug Ο Power cord IEC320 type ...

Page 8: ...Screw mounting on a wall The case is featured two holes on the case Screw the injector over the screw holes on a wall securely Wall mounting The case bottom is designed with a hole for mounting the injector on a wall ...

Page 9: ...ge within a range of 90 264VAC It supports the commercial power available worldwide Use a proper AC power cable matching the AC outlet in your area Note Make sure the DC plug is properly seated in the DC jack before applying AC power Connecting network cables 1 Connect IN jack to the switched port of a Fast Ethernet switch or Gigabit Ethernet switch 2 Connect OUT jack to the 802 3af compliant powe...

Page 10: ...10 Application Supporting PoE wireless Access Point 802 3af PD Supporting PoE media converter 802 3af PD ...

Reviews: