SETTING THE INVERTER ID
The inverter ID is used to identify the inverter in a RS485 connection
Set a different inverter ID for each inverter in the PV plant. Otherwise, the inverters cannot be correctly
identified.
On the last inverter in the RS485 connection, switch on the RS485 termination resistor
SET DATE & TIME OF INVERTER
For a precise calculation of the statistics in the inverter itself and in a monitoring system, date and time have to
be correct.
SET COMMUNICATION PROTOCOL
NOTE: The above details are mentioned in the
Installation & Operation Manual
for Kstar KSG-30K/36K/50K/(60K-
HV)/60K on Page 28.
Op
tion 5 under Settings Menu- 485 address
Press UP/DOWN to increase or decrease the input figure, confirm input and
return back setup interface by pressing ENTER button, press ESC button to
cancel input and return back setup interface;
the input numerical value is between 1 and 32.
Option 10 under Settings Menu- Date/Time
Press UP/DOWN to increase or decrease the input figure; press ENTER button
to move the cursor backwards, confirm input and return back setup
interface ; and move the cursor frontward and return back setup interface
by pressing ESC button.
Option 7 under Settings Menu- 485 Protocol
Press UP/DOWN button to move corresponding options. And confirm
selected option and return back the setup interface by pressing ENTER
button,press ESC button to cancel choice and return back setup interface
Set correct Inverter Ids
Set the Correct Date & Time
Set correct Protocol