KStar KSG-DM 10kW Installation Manual Download Page 2

Multiple Inverters 

 

 Pin 2 & 4 of Inv-1 is connected to Pin 1 & 3 of next inverter in Daisy Chain. 
 
When two or more inverters are in parallel communication, 2P DIP switch beside RS485 of the last one should be 
“ON”. Or else, it may cause communication interruption. That 2P DIP switch is on, means connecting a 120Ω 
communication terminal resistance between the R/T + and R/T - ) 

DEFAULT CONFIGURATION IN TRACKSO IOT GATEWAY 
 
Inverter ID: 1, 2, 3, 4 …. Continuous numbering starting with 1,  (Range: 1 to 247)  
Baud Rate: 9600 (Default) (Values: 9600, 19200, 38400) 
Data Bits: 8 , Stop Bit: 1 , Parity: None 

CONFIGURATION AT THE INVERTER END 

Press Enter on LCD panel and get into settings menu, After entering into the setup interface, the system will 
prompt to input password, the default password is “00000” 

 

SETTING THE BAUD RATE 

If you connect multiple inverters via RS485, set the same baud rate on each inverter. 

Option 6 under Settings Menu- 485 Baudrate 

 

 

Press UP/DOWN button to move corresponding options. And confirm 
selected option and return back the setup interface by pressing ENTER 
button, press ESC button to cancel choice and return back setup 
interface. 

 Set the Inverter baud rate to 9600 

 

 