Installation and Operation Manual
36
Altitude (m)
≤2000
Ventilation
natural cooling
Consumption During
Night
Time (W)
<0.2
Noise (dB)
<25
Communication
LCD
4 lines characters display, the content can be exchanged by
pressing button
Communication Interface
RS232 & RS485
Mechanical Parameters
Dimensions (W×D×H)
mm
329×149×466
Weight (Kg)
14.7
15.1
15.1
15.7
15.7
Table 9.2 Grid Specification(single-phase)
Grid
Specification
Output Voltage
Range (Vac)
Output Frequency
Range (Hz)
Boot wait
time (S)
China
187 - 252
48 - 50.5
60
Germany
196 - 264
47.5 - 51.5
60
Australia
180 - 265
47 - 52
60
Italy
184 - 276
49.7 - 50.3
60
Spain
196 - 253
48 - 50.5
180
U.K.
184 - 264
47 - 52
180
Hungary
196 - 253
49 - 51
300
Belgium
184 - 264
47.5 - 51.5
60
New Zealand
180 - 265
45 - 52
60
Greece
184 - 264
49.5 - 50.5
180
France
184 - 264
47.5 - 50.4
60
Metro
150 - 264
49 - 51
150
Thailand
150 - 264
47 - 52
60
Local
150 - 280
45 - 55
60
60Hz
184 - 276
59.5 - 60.5
60