background image

KSR Lighting Ltd, Unit E Hazleton Interchange, Lakesmere Road, Horndean, Hampshire, PO8 9JU

03.03.2021RTG

PIR Controls

Read these instructions before commencing installation. Please give these instructions to the owner/occupier after
installation to retain for future reference/maintainence.

Siena CCT LED

LED Floodlight with PIR

KSR Lighting Aftersales: 023 92 674343
E-mail: [email protected]

Description of Operation

This floodlight comes complete with an passive infrared detector. The lamp switches on when movement in the
surrounding area is detected or when natural day light becomes dusk. Ensure to replace any cracked shield / glass.

Operation Mode

When power is switched on, the PIR detector enters into the warm up

period (approx 15-30 seconds), the PIR will then change to the AUTO MODE
automatically, during the AUTO MODE walk testing can be easily carried out.

Walk Testing

Before walk testing, please put the LUX control to the day position (    ) and the TIME control to minimum (fully

clockwise). Once the PIR sensor receives a valid trigger signal (such as body movement) within its detection area,
the load / lamp will be turned on for a duration time, You will obtain the desired detection area by walking slowly
through the area to be covered.

Adjusting the Lux Control Level

The LUX control module has an in built sensing device (photocell) that detects daylight (    ) and darkness (    )

Rotating the LUX control anti-clockwise will take it from light to dark, set at desired level.

Note: 

You will need to wait 5 secs for the stability of the photocell (CDS) when adjusting the LUX control.

Adjusting the Duration Time

The length of time sensor remains on after activation can be adjusted from 10 secs to 9 mins. Rotate the TIME
control clockwise to increase the duration.

Note: 

Once the load has been triggered by the PIR detector any subsequent detection will restart the time period.

Adjusting the Sensitivity

With this control the sensitivity of the detector can be adjusted, turn the SENS control anti-clockwise to increase the
sensitivity.

Manual Override

With the floodlight powered on, switch the power off and then back on in less than 3 seconds.
This will override the sensor and the light will stay on.
To revert back to auto mode power off the floodlight for more than 5 seconds and power back on.

PIR Specification

Detection Range:

 120°

Detection Distance:

 2~10m(adjustable)

Time Delay:

 10sec ±5sec ~ 7min ±2min (adjustable)

Ambient Light:

 <3 ~ 2000 LUX (adjustable)

Detection Motion Speed:

 0.6-1.5m/s

Working Temperature:

 -10

°

c ~ +40

°

c

Working Humidity:

 <93%RH

Installation Height:

 1-3m

Override Mode:

 Yes

PIR Adjustments

-

+

LUX

Please Note: After adjusting the PIR please make
sure the screw on the knuckle joint that allows you

to adjust the angle of the PIR is tightened to ensure
the fitting retains it's IP65 rating failure to do this

could result in water ingress and premature failure
of the luminaire.

SENS

TIME

-

+

Reviews: