background image

8.

Ñ

Battery Assembly Diagram

D

Front Cover

E

Cabin Cover

F

AA-size Battery

G

Rear Cover

D

E

F

G

Positive Pole Down

STRUCTURE <D>

Summary of Contents for MG6-F1

Page 1: ...GLOSSMETER USER s MANUAL...

Page 2: ...n Street Dongbin Industrial Zone Donghai Bincheng Quanzhou 362000 China Tel 86 595 22391040 Fax 86 595 22391048 E mail sales ksj cn Website www ksj cn KSJ Photoelectrical Instruments Co Ltd www glossm...

Page 3: ...1 CONTENTS Specifications Structure Operation Maintenance Packing List Warranty and Support 3 5 9 12 13 14...

Page 4: ...arnishes printing ink etc Decorative materials such as marble granite polishing brick ceramic tile and so on The other kinds of materials and objects such as plastic woodenware paper etc Main Applicat...

Page 5: ...IFICATIONS A Specifications Unit Reading Range Measuring Range Resolution Deviation Zero point Deviation Stability Measuring Area Measurement Aperture Incidence Angle GU GU GU GU GU GU mm 60 20 10 30...

Page 6: ...n Volume mm 3 123 65 38 Main Weight g Rechargeable or alkaline 300 Specifications Unit One AA size battery 1 2V 1 5V It s different to battery types An alkaline battery may last the meter to work more...

Page 7: ...5 Front of Main Device 1 2 3 5 4 1 Front Cover 2 Measuring Mark 3 Info Labels 4 Measurement Aperture 5 Battery Cabin STRUCTURE A...

Page 8: ...6 Rear of Main Device 6 Display Screen 7 Calibration Knob 8 Knob Protector 9 On Off Button 6 7 8 9 STRUCTURE B...

Page 9: ...7 Holder With Calibration Tile A Holder B Calibration Tile Working Standard C Gloss Value Label A B C STRUCTURE C...

Page 10: ...8 Battery Assembly Diagram D Front Cover E Cabin Cover F AA size Battery G Rear Cover D E F G Positive Pole Down STRUCTURE D...

Page 11: ...ading to the correct value that is labeled in the holder The main device must be located in the holder properly Measurement Remove the holder and lay the Measuring Aperture just against the position t...

Page 12: ...ld be less than or equal to 1 GU If the deviation goes beyond this scope it s shown that the certified gloss values of the working standards may be changed Thus the gloss values should be certified ag...

Page 13: ...nol Calibrating measuring and checking should be carried out at a same ambient temperature Too big difference in temperature would bring about the numerical excursion While measuring keep environment...

Page 14: ...lean both the Calibration Tile and the Checking Tile Remove the battery to prevent corrosion for a long period store After measurement the meter should be turned off at once in order to save energy Al...

Page 15: ...T Main Device Model MG6 F1 MG6 S1 Calibration Holder with Calibrating Tile Working Standard Checking Tile Spare Working Standard User Manual Certification Guarantee Card 1 set 1 piece 1 piece 1 piece...

Page 16: ...de glossmeter customizing for a special application Note If your gloss meter needs service carry it to the local reseller for repair The meter should not be taken down at will in order to avoid precis...

Page 17: ...NOTE FOR MAINTENANCE Date Signature Description 15...

Reviews: