EN
15
LED COLORS
MEANING
GREEN FIX
IR Detection without alarm
BLUE FIX
MV Detection without alarm
RED FIX
Alarm Detection ( IR & MW )
BLUE FLASHING
Masking detection
WHITE FLASHING
Phase Heating / Calibration
NOTE:
The heating phase lasts at most 60 seconds, and it starts at power up or toggling a DIP SWITCH.
Even if the system status (LED) is disabled through DIP 1 or input “I”, in case of masking
the LED will blink a blue color.
LED MEANING
PROGRAMMING
DIP SWITCH
FUNCTIONALITY
LED
ON > Enable LED for signaling STATE / EVENTS
ANTIMASKING
END OF LINE RESISTORS
TAMPER ANALYSIS
OFF > LED Always Off
OFF > Disable antimask
ON > Enable tamper via
MEMS
OFF > Disable tamper via
MEMS
ON > End of Line Resistors for wiring to lares series control panel
OFF > End of Line Resistors NOT ENABLED
ON
1
2
3
4
DIP-SWITCH
Programmable Functionality
Default Configuration ( ON / ON /ON / OFF )
Note: Calibration Time about 60 seconds
ON > Enable antimask
NOTE: After enabling/disabling one functionality, it is not necessary to restart the detector.
After toggling DIP SWITCH 2 or 3 , the phase of Heating/Calibration starts, highlighted by the LED
blinking white.