INSTALLATION INSTRUCTIONS
1. The wall temperature have to be similar to walls/floor of monitored area
2. The sensor have to be aimed away from windows and reflected sunlight
3. The sensor have to be aimed away from heaters or heater/cooler outlets
4. The sensor have to be aimed so that likely intruder paths cross three views
5. Please leave clear line-of-sight from sensor to monitored area
Note: glass will block PIR sensor ’s view; metal will block microwave sensor’s view
Warning:
Do not partially or completely hinder the view of the detector
Wall Mounting
1. The sensor base have to be fastened flat on vertical wall (± 2 degrees)
2. The sensor have to be mounted at 2,3m or 3m height from the floor
Mounting Bracket
1. Bracket fastened to semi-vertical surface (± 15 degrees)
2. The sensor have to be fastened flat on bracket on vertical wall
OPERATION PROGRAMMING JUMPERS
If there is a way for intruders to pass only a very short distance in the sensor’s view
or if aggressive detection is required then use HIGH sensitivity (JP2 OFF) otherwise
LOW sensitivity is fine for ordinary applications.
FUNCTION
JP
ON
OFF
PIR / MW LED
1
ENABLED
DISABLED*
Number of Steps
2
3 - 5
1 - 3
Sensitivity
3
LOW
HIGH
Alarm LED
ENABLED
DISABLED
*Using this setting you can remotely manage the switching on of the LEDs via the
clamp ‘LED EN’. By applying a 12V voltage (system armed) the LEDs will signal an
alarm detection.