code R30015.110en www.kseniasecurity.com
ed. 01/2021
INSTALLATION
Installing
opis
PCBA inside the metallic box (accessory code KSI7403130.010 or KSI7404130.010) with
power station (
adjust it at 14.2V
):
1. Fix the metal cabinet to the wall using Ø 0.32 inch screws (options)
2. Place the
opis
PCBA in the metallic box with power supply charger
3. Perform the necessary links between the
opis
PCBA and the power supply, as described in the paragraph
“DESCRIPTION OF POWER SUPPLY STATION CONNECTIONS” page 4
4. Ensure the cables to the fixing holes
5. Arrange outside the Panel an isolating device (i.e. Circuit Breaker Device 16A Curve C).
6. The power supply has an internal protection fuse (50W - F3.15AL).
7. Wire the earth connection directly on the power supply unit.
8. The power supply conductors must be 0.6 inch.² minimum section.
9. In case of failure or maintenance, the opening of the metallic box must be carried out by authorized
personal.
QUANTITY DATA
CERTIFICATIONS
Europe - RoHS, CE
EN50131 Grade 3 - class II
T031:2014
Technical data, appearance, functionality and other product characteristics may change without notice.
lares 4.0 models
wls 96
16
40
40 wls
140 wls
644 wls
Maximum number of expansion
modules isolator opis
2
4
12
12
20
32