Ksenia opis KSI2400000.300 Installation Manual Download Page 3

code R30015.110en                                                                                                                                                                          www.kseniasecurity.com
ed. 01/2021

POWER SUPPLY STATION TECHNICAL DATA

Power supply voltage: 230 V~ -15/+10% 50 Hz 0.8 A

Power Supply Battery Charger* (Type A norm EN50131-6): 14.2V ± 1% 50W

Current consumption (medium): 50mA

Current consumption (max): 100mA

Maximum current available for external devices: 1450 mA grade 2 - 0.55 mA grade 3

Max. output voltage ripple: 13.8 V- da 10 a 15 V-   120 mV

Max. current for battery charging: 750 mA

Maximum battery recharge time to 80%: 12 V – 18 Ah  24 h

Deep discharge voltage protection: 10 V

Low battery threshold (restore): 11 V- (12.5 V-)

Low voltage threshold: 11 V-

Over voltage protection voltage: 17.5 V

Backup battery: 18Ah

Overall dimensions (WxHxD): 325x400x90 mm

Weight (with battery): 4.2 Kg (10 Kg)

Temperature operating range: +5 / +40 °C  - Humidity (not condensed): 95 %

* Note: The power supply is calibrated at 15V, compatible with control panels of lares 4.0 family. When 
using with lares control panels or with opis, act on the trimmer of charger to adjust the voltage at 14.2V.

  

  LEDs SIGNALATION  (M - B - S)

M

Power Supply status

Steady: Correctly working
Off: Power supply fault or missing AC network

B

Battery Voltage status

Steady: Correctly working
Off: Fault or low battery level

S

System Status

Steady: Correctly working
Flashing: Tamper and/or BUS IN connection fault

detail of PCBA: LEDs