FUNCTIONS

• Display of system status

• Display of functioning parameters ( date/time, active GSM network, GSM level, etc)

• System commands (complete or partial arming, reset, activation of outputs terminals, phone calls,

etc.)

• Full Programming of system parameters

• Programming of local parameters (audio volume, backlight levels)

• KP functionality exclusion for front cleaning purposes

• Remote Listening

• Vocal messages recording

• RFID/NFC

 Tag reading to arm and disarm the intrusion detection systems set up with the 

lares

 

devices.

OPTIONALS

KSI7500000.000

 / KIT 1,5 m. cable for GSM/GPRS programming

KSI2100001.300

 / Table sustainer

KSI2100002.300

 / KIT 

ergo

 keypad

INSTALLATION

BUILT-IN INSTALLATION (WITH DIN 503 BOX) OR DIRECTLY ON THE WALL

INSTALLATION WITH TABLE SUSTAINER

The keypad 

ergo

 can be installed directly on a wall or put in an DIN 503 box set in the wall or leant on a 

plain surface by means of the proper sustainer.

1. Push the cable through to the proper opening.

2. Fix the keypad base to the DIN 503 box with the supplied screws opening the proper eyelets. To fix

the keypad base directly to a wall, use proper plugs (not supplied) through the proper eyelets.

3. Connect the cables to the terminals on the rear of the keypad.

4. Fit in the PCBA on the left side of the keypad base, keeping the display in the front and the clamps

on the back, then press the right side until a double-click is heard.

5. Insert a coloured Lexan at choice into the cover.

6. Close the cover properly.

1. Install, with a light pressure, the part 1 of the table sustainer on the back of the keypad base.

2. Fit in the part 2 of the sustainer on the part 1 by the mean of the proper hinge.

3. Push the cable through to the proper opening.

4. Connect the cables to the terminals on the rear of the keypad.

5. Fit in the PCBA on the left side of the keypad base, keeping the display in the front and the clamps

on the back, then press the right side until a double-click is heard.

6. Insert a coloured Lexan at choice into the cover.

7. Close the cover properly.

8. Use the optional cable for the programming of the communicator GSM/GPRS 

gemino

.

Summary of Contents for ergo

Page 1: ...KSI2100000 300 MULTIFUNCTION LCD KEYPAD QUICK INSTALLATION AND PROGRAMMING GUIDE ...

Page 2: ...k solution can be chosen thanks to the included stylish sustainer parts The ergo keypad has been conceived to be linked both to Universal GSM GPRS Communicator geminoTM and Ksenia intrusion control panel lares since differently to any other similar devices it works also as programming unit making the installer s life much easier by avoiding the need of having a PC with for the Communicator or the ...

Page 3: ...proper opening 2 Fix the keypad base to the DIN 503 box with the supplied screws opening the proper eyelets To fix the keypad base directly to a wall use proper plugs not supplied through the proper eyelets 3 Connect the cables to the terminals on the rear of the keypad 4 Fit in the PCBA on the left side of the keypad base keeping the display in the front and the clamps on the back then press the ...

Page 4: ...Test procedures depends on the system configuration Ask to the installer for the procedures to be followed Ksenia Security srl shall not be responsible for damage arising from improper installation or maintenance by unauthorized personnel The content of this guide can change without prior notice from KSENIA SECURITY Information for users Disposal RAEE Directive Warning Do not use an ordinary dustb...

Page 5: ...ounting to take advantage of tear tamper 1 3 4 2 In order to maintain the conformity to the norms listed on page 21 this installation option can t be used FIGURE 3 PARTS DESCRIPTION AND PCBA TERMINALS 7 3 8 8 1 6 5 2 4 1 Connection Clamps A B Connection clamps on KSI BUS for devices All the devices have to be connected in parallel it is necessary to connect each clamp with an equally named one cla...

Page 6: ...pad with 1 a 9 and keys 2 ESC key 3 ENTER key Scroll also including 4 1 Left arrow 4 2 Down arrow 4 3 Right arrow 4 4 Up arrow 4 5 Display 6 RFID NFC Area To open the transparent front cover please proceed as follows Insert a flat screwdriver in the slot Pull outward OPEN TRANSPARENT COVER 1 2 ...

Page 7: ...itivity setting available in 3 different levels by selecting it from the keypad menù or by programming the setting taking advantage of the basis software At last a small test game Insert your PIN surf in the menù with the circular scroll select a menù for example the one which allows to insert a phone number in the phone book and insert it by digiting on the keypad After few minutes only you ll be...

Page 8: ...s in case the string its being edited the first number flashes when a numeric data or a phone number is being edited During the editing phase a further pressure on the ENTER key confirms the immission or modification of the data which will be sent to gemino or lares that will store it and the ergo display permits to show the following data the subsequent menu or the data itself If Enter key is pus...

Page 9: ...e about 0 5 sec exerted on the 4 3 area of the figure 5 allows to slide backwards along a line if it is longer than the 16 characters the ergo display can show The forward slide can work in different ways depending on the data we are working on if we are browsing a menu it will slide 16 characters at any one time while during data editing it will only slide character at any one time In a data ente...

Page 10: ...71 215 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 30 959 0930 www delton hu E mail info delton hu Web www delton hu 1141 Budapest Fogarasi út 77 Tel 220 7940 220 7814 220 7959 220 8881 364 3428 Fax 220 7940 Mobil 30 531 5454 30 939 9989 ...