3 Transport/Temporary Storage/Disposal
12 of 44
Vitastage
CAUTION
Damage during storage due to humidity, dirt, or vermin
Corrosion/contamination of the pump (set)!
▷
For outdoor storage cover the packed or unpacked pump (set) and accessories
with waterproof material.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump!
▷
Clean and cover pump openings and connections as required prior to putting
the pump into storage.
Store the pump (set) in a dry, protected room where the atmospheric humidity is as
constant as possible.
Rotate the shaft by hand once a month, e.g. via the motor fan.
If properly stored indoors, the pump set is protected for a maximum of 12 months.
New pumps/pump sets are supplied by our factory duly prepared for storage.
For storing a pump (set) which has already been operated, the shutdown measures
must be adhered to.
3.4 Return to supplier
1.
Prior to returning the product to the supplier, flush and clean it, particularly if it
has been used in noxious, explosive, hot or other hazardous fluids.
2.
If the product has been used in fluids whose residues could lead to corrosion
damage in the presence of atmospheric humidity or could ignite upon contact
with oxygen, the product must also be neutralised and treated with anhydrous
inert gas to ensure drying.
3.
Always complete and enclose a certificate of decontamination when returning
the product.
Indicate any safety measures and decontamination measures taken.