7.3
Drainage/disposal
WARNING
Fluids posing a health hazard
Hazardous to persons and the environment!
▷
Collect and properly dispose of flushing liquid and any fluid residues.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1. Always flush the pump if it has been used for handling noxious, hot or other
hazardous fluids.
Always flush and clean the pump before transporting it to the workshop. Provide
a cleaning record for the pump.
7.4
Dismantling the pump set
7.4.1 General information/Safety regulations
WARNING
Unqualified personnel performing work on the pump (set)
Risk of personal injury!
▷
Always have repair and maintenance work performed by specially trained,
qualified personnel.
WARNING
Hot surface
Risk of personal injury!
▷
Allow the pump set to cool down to ambient temperature.
Observe the general safety instructions and information.
For any work on the motor, observe the instructions of the relevant motor
manufacturer.
For dismantling and reassembly observe the exploded view and the general assembly
drawing. (
NOTE
All maintenance, service and installation work can be carried out by KSB Service. Find
your contact in the attached "Addresses" booklet or on the Internet at
".
DANGER
Insufficient preparation of work on the pump (set)
Risk of personal injury!
▷
Properly shut down the pump set. (
▷
Close the shut-off elements in the suction and discharge line.
▷
Drain the pump and release the pump pressure. (
▷
Allow the pump set to cool down to ambient temperature.
NOTE
After a prolonged period of operation the individual parts may be hard to pull off the
shaft. If this is the case, use a brand name penetrating agent and/or - if possible - an
appropriate pull-off device.
7 Servicing/Maintenance
24 of 36
Trialine / Trialine Z