8 Troubleshooting
41 of 52
KSB SuPremE
A B C D E
F G H
I Possible cause
Remedy
-
-
-
✘ ✘
-
-
-
- Drive overload
Lower the power input by reducing
rotational speed, then check the drive/
pump/load for blockage.
-
-
-
-
✘
-
-
-
- Temperature of power electronics or
motor winding too high (particularly at
high torque and low speed)
Reduce the ambient temperature by
improving ventilation.
Improve cooling by cleaning the cooling
fins.
Ensure the intake opening for the motor
fan is not blocked.
Ensure that the motor fan is working
properly.
Reduce the power input by changing the
operating point (system-specific).
Check the permissible load and, if
necessary, use external cooling.
-
-
-
-
-
✘
-
-
- Damage to the bearings
Check bearings and replace if necessary.
-
-
-
-
-
✘
-
-
- Rubbing contact between rotor and stator Check bearings and replace if necessary.
Check rotor and replace if necessary.
-
-
-
-
-
-
✘
-
- Rotor unbalance
Check key convention applicable to the
shaft and output element; remove rotor
and re-balance if required.
-
-
-
-
-
-
✘
-
- Improper installation
Check the foundation, the place of
installation and the mounting surface.
-
-
-
-
-
-
-
✘
- Incorrect connection of pump/load
Check correct alignment between motor
and driven machine, check coupling.
-
-
-
-
-
-
-
-
✘
Wrong direction of rotation setting
Change the direction of rotation by
altering the parameters of the frequency
inverter or interchanging two phase
conductors.
Summary of Contents for SuPreme Series
Page 1: ...Synchronous Reluctance Motor KSB SuPremE Installation Operating Manual ...