5 Installation at Site
20 of 72
Sewatec (60 Hz)
3.
Drill the holes as specified in the table "Chemical anchor dimensions". Then
clean the holes.
WARNING
Improper handling of mortar cartridge
Skin sensitization and/or irritation!
▷
Wear suitable protective clothing.
4.
Insert the mortar cartridges into the drilled holes.
Observe the curing times of the mortar cartridges!
5.
Insert threaded rods into the corresponding drilled holes with an electric tool
(e.g. impact drill, hammer drill).
6.
After the curing time (see table), tighten the chemical anchors (3) evenly and
tightly.
7.
Grout the baseplate using low-shrinkage concrete.
Chemical anchor
dimensions
t
2
t
1
SW
1
d
1
SW
2
d
2
l
1
Fig. 4:
Dimensions
Table 9:
Chemical anchor dimensions [
″
]
Size
(d
1
× l
1
)
d
2
t
1
t
2
SW
1
3)
SW
2
3)
M
d1
[
″
]
[
″
]
[
″
]
[
″
]
[
″
]
[ft lb]
3
/
8
× 5
1
/
8
″
7
/
16
7
/
8
3
9
/
16
11
/
16
1
/
4
14,75
7
/
16
× 6
5
/
16
″
9
/
16
1
4
5
/
16
3
/
4
5
/
16
29,50
5
/
8
× 7
1
/
2
″
11
/
16
1
3
/
8
4
15
/
16
15
/
16
7
/
16
44,25
13
/
16
× 10
1
/
4
″
1
2
9
/
16
6
11
/
16
1
3
/
16
9
/
16
88,50
15
/
16
× 11
13
/
16
″
4)
1
1
/
8
2
9
/
16
8
1
/
4
1
7
/
16
11
/
16
132,76
1
3
/
16
× 14
15
/
16
″
4)
1
3
/
8
2
9
/
16
11
1
13
/
16
-
295,02
Table 10:
Chemical anchor dimensions [mm]
Size
(d
1
× l
1
)
d
2
t
1
t
2
SW
1
3)
SW
2
3)
M
d1
[mm] [mm] [mm] [mm] [mm]
[Nm]
M10 × 130
12
22
90
17
6
20
M12 × 160
14
25
110
19
8
40
M16 × 190
18
35
125
24
12
60
M20 × 260
25
65
170
30
14
120
M24 × 300
4)
28
65
210
36
17
180
M30 × 380
4)
35
65
280
46
-
400
3)
SW = Width across flats
4)
Mounting accessories of the respective manufacturer are required.