6 Commissioning/Start-up/Shutdown
32 of 60
Multi Eco
6.1.5 Start-up
DANGER
Non-compliance with the permissible pressure and temperature limits if the pump
is operated with the suction and discharge lines closed.
Leakage of hot or toxic fluids!
▷
Never operate the pump with the shut-off elements in the suction line and/or
discharge line closed.
▷
Only start up the pump set with the discharge-side gate valve slightly or fully
open.
CAUTION
Excessive temperatures due to dry running or excessive gas content in the fluid
handled
Damage to the pump set!
▷
Never operate the pump set without liquid fill.
▷
Prime the pump as per operating instructions.
▷
Always operate the pump within the permissible operating range.
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
▷
Switch off the pump (set) immediately.
▷
Eliminate the causes before returning the pump set to service.
1.
Plug the mains plug into the mains socket.
2.
Switch on the pump set. (Multi Eco P)