7 Servicing/Maintenance
51 of 96
Magnochem-Bloc
7.4 Dismantling the pump set
7.4.1 General information/Safety regulations
DANGER
Strong magnetic field in the area of the magnetic coupling or the individual
magnets
Danger of death for persons with pacemaker!
Interference with magnetic data carriers, electronic devices, components and
instruments!
Uncontrolled magnetic attraction forces between magnet-equipped components,
tools or similar!
▷
Keep a safety distance of at least 0.3 m.
▷
Also observe the additional instructions. (
WARNING
Hot surface
Risk of injury!
▷
Allow the pump set to cool down to ambient temperature.
WARNING
Unqualified personnel performing work on the pump (set)
Risk of injury!
▷
Always have repair work and maintenance work performed by specially trained,
qualified personnel.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
Observe the general safety instructions. (
For any work on the motor, observe the instructions of the motor manufacturer
(refer to manufacturer's technical product literature).
For dismantling and reassembly observe the exploded views and the general
assembly drawing. (
In the event of damage, you can always contact our service departments.
DANGER
Insufficient preparation of work on the pump (set)
Risk of injury!
▷
Properly shut down the pump set. (
▷
Close the shut-off elements in the suction line and discharge line.
▷
Drain the pump and release the pump pressure.
▷
Shut off any auxiliary feed lines.
▷
Allow the pump set to cool down to ambient temperature.