Pump Switchgear / Control Systems
LevelControl Control Units
24
LevelControl Basic 2
4041.5/12-EN
LevelControl Basic 2 for Amarex KRT
Documented device versions
Control units for single-pump station, ATEX-compliant version
Size
Float switch
incl. 4 - 20 mA input
Float switch
Pneumatic
Bubbler control
xFNO
xFEO (ATEX-compliant)
xPEO (ATEX-compliant)
xLEO (ATEX-compliant)
400 V: 6,3 - 10 A
BS1 400
DFNO
100
BS1 400
DFEO
100
BS1 400
DPEO
100
BS1 400
DLEO
100
400 V: 9 - 14 A
BS1 400
SFNO
140
BS1 400
SFEO
140
BS1 400
SPEO
140
BS1 400
SLEO
140
400 V: 13 - 18 A
BS1 400
SFNO
180
BS1 400
SFEO
180
BS1 400
SPEO
180
BS1 400
SLEO
180
400 V: 17 - 23 A
BS1 400
SFNO
230
BS1 400
SFEO
230
BS1 400
SPEO
230
BS1 400
SLEO
230
400 V: 20 - 25 A
BS1 400
SFNO
250
BS1 400
SFEO
250
BS1 400
SPEO
250
BS1 400
SLEO
250
400 V: 25 - 40 A
BS1 400
SFNO
400
BS1 400
SFEO
400
BS1 400
SPEO
400
BS1 400
SLEO
400
400 V: 40 - 63 A
BS1 400
SFNO
630
BS1 400
SFEO
630
BS1 400
SPEO
630
BS1 400
SLEO
630
Control units for dual-pump station, ATEX-compliant version
Size
Float switch
incl. 4 - 20 mA input
Float switch
Pneumatic
Bubbler control
xFNO
xFEO (ATEX-compliant)
xPEO (ATEX-compliant)
xLEO (ATEX-compliant)
400 V: 6,3 - 10 A
BS2 400
DFNO
100
BS2 400
DFEO
100
BS2 400
DPEO
100
BS2 400
DLEO
100
400 V: 9 - 14 A
BS2 400
SFNO
140
BS2 400
SFEO
140
BS2 400
SPEO
140
BS2 400
SLEO
140
400 V: 13 - 18 A
BS2 400
SFNO
180
BS2 400
SFEO
180
BS2 400
SPEO
180
BS2 400
SLEO
180
400 V: 17 - 23 A
BS2 400
SFNO
230
BS2 400
SFEO
230
BS2 400
SPEO
230
BS2 400
SLEO
230
400 V: 20 - 25 A
BS2 400
SFNO
250
BS2 400
SFEO
250
BS2 400
SPEO
250
BS2 400
SLEO
250
400 V: 25 - 40 A
BS2 400
SFNO
400
BS2 400
SFEO
400
BS2 400
SPEO
400
BS2 400
SLEO
400
400 V: 40 - 63 A
BS2 400
SFNO
630
BS2 400
SFEO
630
BS2 400
SPEO
630
BS2 400
SLEO
630
Functional comparison
Symbols key
Symbol
Description
d
Digital display of switching points
o
Optional
✘
Control unit feature
-
Not a control unit feature
Comparison of functions of Amarex KRT single-pump stations and dual-pump stations
Feature
Single-pump station
Dual-pump station
xFNO
xFEO
xPEO
xLEO
xFNO
xFEO
xPEO
xLEO
Functions
Draining
✘
✘
Stand-by pump: 1 pump redundant
-
✘
Pump changeover after each start
-
✘
Pump changeover in event of fault
-
✘
ATEX mode
-
✘
✘
✘
-
✘
✘
✘
Peak load operation function
-
✘
Runtime limitation
✘
✘
OFF via after-run time
✘
✘
OFF via level
✘
✘
Functional check run after idle period
✘
✘
Alert history
✘
✘
Display and operation
7-segment display
✘
✘
Indication of water level
d
✘
d
✘
Operation / fault / pump running
(displayed for each pump)
Multicolour LED
Multicolour LED
General fault (traffic light)
LED
LED
High water
LED
LED
Mains voltage
✘
✘
Summary of Contents for LevelControl Basic 2
Page 1: ...Level Control Unit LevelControl Basic 2 Type Series Booklet...
Page 36: ......