LCV [en-US]
11
Pump Part
Pump Part
Pedestal
Casing
Casing Half
Liner
Plate
Impeller
Sub-base
Outdoor storage with monthly inspection permitted for these parts only
Lay sub-bases flat and do not stack
Shaft
Coat complete part with rust protector and wrap with 6mil/0.15mm VCI (Vapor
Corrosion Inhibitor ) plastic
O-Ring
Gasket
Check expiration date (shelf life is typically 5 years)
Keep dry, out of direct sunlight and away from heat
Bearing
Bearing Isolator
Sealing Washer
Check expiration date (shelf life is typically 1 year)
Refer to Manufacturer’s Storage guidelines
Keep in unopened box provided by the vendor
Keep dry, out of direct sunlight and lay flat
Motor
Sheave
Gear Reducer
Coupling
Bushing
Refer to manufacturer’s storage guidelines
3.2.4
Removal from Storage
Remove rust from machined surfaces using a wire brush.
Remove rust inhibitor from all machined surfaces prior to installation/assembly.
Check the painted surfaces for any signs of corrosion or breaks in the coatings and touch-up as needed.
It is recommended that the bearing assembly be drained before shipment and refilled after relocation or installation.
For grease lubricated units, a fresh application of grease in the amount recommended by the maintenance manual for
a normal lubrication interval should be applied.
Stuffing Box should be checked before start-up and replaced if necessary. Packing may have dried out and need
multiple readjustments during the start-up process.
If the pump is fitted with a mechanical seal, motor, sheave, bushing, coupling, gear reducer, or other auxilarily
equipment be sure to consult the manufacturer’s maintenance manual for any additional storage removal and
commissioning instructions.Consult the Section 6 "Commissioning" before putting the pump into service.
Summary of Contents for LCV