5 Installation at Site
28 of 74
HPK-L
1136.8/15-EN
Fig. 13:
Quench connections
24A
Quench outlet
24E
Quench inlet
For pump sets with two mechanical seals in tandem arrangement, connect an
unpressurised quench liquid supply to the "Quench outlet" (24E) and "Quench
inlet" (24A) connections.
5.4 Enclosure/insulation
DANGER
An explosive atmosphere forms due to insufficient venting
Explosion hazard!
▷
Never close or cover the perforation of the bearing bracket guards (e.g. by
insulation).
WARNING
The volute casing and casing/discharge cover take on the same temperature as the
fluid handled
Risk of burns!
▷
Insulate the volute casing.
▷
Fit protective equipment.
CAUTION
Heat build-up in the bearing bracket
Damage to the bearing!
▷
Never insulate the bearing bracket, bearing bracket lantern and casing cover.
5.5 Checking the coupling alignment
DANGER
Inadmissible temperatures at the coupling or bearings due to misalignment of the
coupling
Explosion hazard!
Risk of burns!
▷
Make sure that the coupling is correctly aligned at all times.