5 Installation at Site
18 of 52
Etaline-R
5 Installation at Site
5.1 Safety regulations
DANGER
Improper installation in potentially explosive atmospheres
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information given in the data sheet and on the pump/motor name
plates.
5.2 Checks to be carried out prior to installation
Place of installation
WARNING
Installation on mounting surface which is unsecured and cannot support the load
Personal injury and damage to property!
▷
Use a concrete of compressive strength class C12/15 which meets the
requirements of exposure class XC1 to EN 206-1.
▷
The mounting surface must have set and must be completely horizontal and
even.
▷
Observe the weights indicated.
1.
Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
5.3 Installing the pump set
CAUTION
Dry running / Ingress of leakage into the motor
Damage to the motor!
▷
Always install the pump set in vertical position.