5 Installation at Site
18 of 40
Emporia MB
CAUTION
Small parts in the motor space
Damage to the pump set!
▷
Never drop small parts into the motor space.
▷
After the electrical connection work on the the pump set has been completed,
check that no small parts have fallen into the motor space. If they have, remove
them.
1.
Check the available mains voltage against the data on the motor name plate.
2.
Select an appropriate start-up method. Pump sets with a nominal current > 10 A
must be wired for star-delta starting.
NOTE
A motor protection device is recommended.
Star-delta starting
Fig. 4:
Circuit diagram for star-delta starting
Pump sets, single-phase
Fig. 5:
Circuit diagram of single-phase pump sets