KSB Compacta Supplementary Operating Manual Download Page 6

2 Safety

6 of 12

Compacta / mini-Compacta

2.4 Personnel qualification and training

All personnel involved must be fully qualified to install, operate, maintain and
inspect the machinery this manual refers to.

The responsibilities, competence and supervision of all personnel involved in
installation, operation, maintenance and inspection must be clearly defined by the
operator.

Deficits in knowledge must be rectified by sufficiently trained specialist personnel
training and instructing the personnel who will carry out the respective tasks. If
required, the operator can commission the manufacturer/supplier to train the
personnel.

Training on the pump (set) must always be supervised by technical specialist
personnel.

2.5 Consequences and risks caused by non-compliance with these operating

instructions

Non-compliance with this supplementary operating manual will lead to
forfeiture of warranty cover and of any and all rights to claims for damages.

Non-compliance can, for example, have the following consequences:

Hazards to persons due to electrical, thermal, mechanical and chemical
effects and explosions

Failure of important product functions

Failure of prescribed maintenance and servicing practices

Hazard to the environment due to leakage of hazardous substances

2.6 Safety awareness

In addition to the safety information contained in this manual and the intended use,
the following safety regulations shall be complied with: 

Accident prevention, health and safety regulations

Explosion protection regulations

Safety regulations for handling hazardous substances

Applicable standards and laws

2.7 Safety information for the operator/user

Fit protective equipment (e.g. contact guards) supplied by the operator for hot,
cold or moving parts, and check that the equipment functions properly.

Do not remove any protective equipment (e.g. contact guards) during operation.

Provide the personnel with protective equipment and make sure it is used.

Contain leakages (e.g. at the shaft seal) of hazardous fluids handled (e.g.
explosive, toxic, hot) so as to avoid any danger to persons and the environment.
Adhere to all relevant laws.

Eliminate all electrical hazards. (In this respect refer to the applicable national
safety regulations and/or regulations issued by the local energy supply
companies.)

If shutting down the pump does not increase potential risk, fit an emergency-
stop control device in the immediate vicinity of the pump (set) during pump set
installation.

2.8 Safety information for maintenance, inspection and installation work

When taking the pump set out of service always adhere to the procedure
described in the supplementary operating manual.

As soon as the work is completed, re-install and/or re-activate any safety-relevant
and protective devices. Before returning the product to service, observe all
instructions on commissioning.

Summary of Contents for Compacta

Page 1: ...Floodable Sewage Lifting Unit Compacta mini Compacta Replacing the Control Unit LevelControl Basic 2 BC Supplementary Operating Manual...

Page 2: ...e contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without the ma...

Page 3: ...General 5 2 3 Intended use 5 2 4 Personnel qualification and training 6 2 5 Consequences and risks caused by non compliance with these operating instructions 6 2 6 Safety awareness 6 2 7 Safety inform...

Page 4: ...control unit 1 2 Target group This supplementary operating manual is aimed at the target group of trained and qualified specialist technical personnel 1 3 Other applicable documents The other applicab...

Page 5: ...aintenance instructions that must be observed to ensure safe operation and prevent personal injury and damage to property are given in the installation operating manual The safety information in all s...

Page 6: ...information contained in this manual and the intended use the following safety regulations shall be complied with Accident prevention health and safety regulations Explosion protection regulations Saf...

Page 7: ...ate the lifting unit outside the limits stated in the data sheet and in the lifting unit s installation operating manual The warranty relating to the operating reliability and safety of the lifting un...

Page 8: ...re that the lifting unit cannot be inadvertently started 2 Open the control unit cover and make sure the control unit is de energised 3 Disconnect the rechargeable battery 4 Clearly mark all conductor...

Page 9: ...e table shown below e g 39 for UZ10 450 D and make the appropriate setting e g 39 using the Up and Down keys of the control unit 5 To confirm press OK 6 Press ESC to exit parameterisation Table 4 Sett...

Page 10: ...Confirm entries Confirm a menu selection When entering numbers Go to the next digit 1 Press the ESC and OK keys simultaneously P3 1 2 1 is displayed 2 Press Up key P3 1 2 2 is displayed 3 Press OK 4...

Page 11: ......

Page 12: ...KSB SE Co KGaA Johann Klein Stra e 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 2317 8003 02 EN...

Reviews: