3 Replacing the LevelControl Basic 2 BC Control Unit
10 of 12
Compacta / mini-Compacta
Setting the inlet nozzle level
Table 5:
Control unit: Navigation keys
Key
Description
Arrow keys (up/down):
▪
Move up/down in the menu options.
▪
Increase/decrease a numerical value
Esc
Escape key:
▪
Cancel entry without saving it.
▪
When entering numbers: Go to the previous digit.
▪
Move up one menu level.
OK
OK key:
▪
Confirm entries.
▪
Confirm a menu selection.
▪
When entering numbers: Go to the next digit.
1.
Press the "ESC" and "OK" keys simultaneously: P3.1.2.1 is displayed.
2.
Press "Up" key: P3.1.2.2 is displayed.
3.
Press "OK".
4.
Select the
lowest
inlet nozzle used from the table below and look up the
relevant setting (e.g. 1 for inlet nozzle level 180 mm). Then make the appropriate
setting (e.g. 1) at the control unit, using the "Up" and "Down" keys.
5.
To confirm the selected value press "OK".
6.
Press "ESC" to exit parameterisation.
Table 6:
Setting the inlet nozzle level
Inlet
[mm]
Setting
180
1
250
2
320
3
700
4
Vertical
5
Summary of Contents for Compacta