6 Commissioning/Start-up/Shutdown
54 of 116
CHTRa
6.2.9 Fitting the protective equipment
DANGER
Improper transport
Danger to life from falling parts!
▷
Observe the safety regulations for transport work. (
▷
Observe the applicable local occupational safety and accident prevention
regulations.
WARNING
Unprotected rotating coupling
Risk of injury by rotating shafts!
▷
Always operate the pump set with a coupling guard.
If the customer specifically requests not to include a coupling guard in KSB's
delivery, then the operator must supply one!
▷
Observe all relevant regulations for selecting a coupling guard.
At the end of all preparatory work to be carried out for start-up, mount all protective
equipment (e.g. coupling guard, contact guard, etc.) and check for correct
functioning.
Operate the pump (set) only after all protective equipment has been fitted.
6.2.9.1 Mounting the coupling guard
1
2
Fig. 28:
Coupling guard (example)
1
Bottom plate
2
Foot fastening (lock strip)
1. Align the coupling guard over the coupling.
2. Make sure the distance to both shaft ends and the coupling components is
sufficient.
3. Fasten the lock strips of the coupling guard to the floor.
4. Fasten the bottom plate with the respective screws.