4 Description of the Pump (Set)
15 of 56
Ama-Drainer 80/100
2331.823/07-EN
Shaft seal
▪
Pump end: 1 mechanical seal
▪
Drive end: 1 mechanical seal
▪
Liquid reservoir between the seals for cooling and lubrication
Impeller type
▪
Open multi-vane impeller
Bearings
▪
Maintenance-free
▪
Grease-packed rolling element bearings sealed for life
Electrical connection
Ama-Drainer 80:
▪
Ready to be plugged in
▪
Power cable and CEE plug with phase inverter
▪
Phase sequence indicator
▪
Over-current trip
Ama-Drainer 100:
▪
Power cable with free cable ends
▪
Control unit available as an accessory
Standard design:
▪
10-metre power cable
Variants B / BH
▪
20 m power cable
4.6 Configuration and function
1
2
3
4
5
6
7
8
9
10
Fig. 2:
Sectional drawing
1 Bearing, motor end
6 Impeller
2 Shaft
7 Foot
3 Bearing, pump end
8 Volute casing