T H E R M A L - I U S E R M A N U A L
10
Application Settings
The settings tab allows the user to change various settings related to the software. This includes
communications, recording and theme settings.
Setting
Description
Default Value
Thermal IP
IP address for the Thermal-i
10.10.1.1
Thermal IP Port
Port address for the Thermal-i
8150
Video IP
IP address for the Thermal-i video feed
10.10.1.1
Video IP Port
Port address for the Thermal-i video feed
8196
Range
Temperature range of the thermal axis on graph
0>150 C
Length
Maximum length that thermal log will run in one session
15Min(s)
Viewport
Initial length of the time axis on thermal graph
3Min(s)
CSV Export
Select to create a CSV of each logging session
Enabled
Video Length
Maximum length that the video recording will run in one session
9Min(s)
Connect
Select to display video feed when a session is started
Enabled
Record
Select to enable video recording
Enabled
Rotate
Rotation of video feed
Left
The logging section provides a shortcut to the video and log files. To
unlock the editing of these path’s, click
on the Logging title 5x.
Note:
All setting changes are saved when the software is closed.
Software Updates
If connected to the internet, the software will automatically check for updates when initializing. If an update
is available, the user will be prompted to install the update.