At Krowne Metal Corporation (KMC) we are dedicated to customer satisfaction. This installation guide is 

 

provided to clarify and answer any questions you may have regarding our line of Backbar Coolers. Please read 
this guide before attempting installation or operation. Thank you for choosing KMC as your Backbar Cooler 
provider.

UNCRATING

Remove all shipping material from unit before operation. Please inspect unit for any hidden freight damage and 
report any damage immediately to Krowne Metal Corp. If included, install optional casters or legs to bottom of 
unit. Please avoid turning unit on it’s side or rear to install accessories. If this can not be avoided, unit must be 
left in the upright position for 24 hrs before operating. All units come equipped with pre-determined mounting 
holes and self starting screws for easy install. (screws are provided only when casters or legs are ordered from 
factory). It is important to check that casters or legs are securely attached with appropriate mounting 

 

hardware.

ELECTRICAL REQUIREMENTS

115 Volt AC, 1 Phase, 60Hz. We recommend using a dedicated 15 amp circuit minimum. 
Self-contained units are supplied with 8’-0”grounded cord standard. 
Remote units come with a terminal block inside the box for a hard wire connection (supplied by the end user).

** DO NOT PLUG UNIT INTO A GFI OUTLET **

PLUMBING

Self-contained units have an evaporating pan and do not require any plumbing hook-up.
Remote units require a drain hook-up. We recommend using 

1

/

2

” tubing and running it thru the same knockout 

used for the refrigeration hook up.

INSTALLING OF SHELVES

Shelves and installation clips are shipped within the cooler inside a separate carton. Shelves can be installed 
based on owner’s preference.

LOCATION

Place unit in desired location and level. 

It is important for the unit to be level or it will not drain properly and 

the doors will not close properly, which in turn will affect the function of the cooler and void any factory 
warranty.

FLOOR SEALING

If required unit can be sealed to floor using a NSF approved clear silicone. Excess sealant should be wiped 
clean.

        

 

 

 

 

Krowne Metal Corporation

100 Haul Rd. Wayne, NJ 07470  •  Toll Free: (800) 631-0442  •  Fax: (973) 872-1129

[email protected]  •  www.krowne.com  •  www.facebook.com/KrowneMetal  •  www.twitter.com/KrowneMetal

 

4

INSTALLATION

Summary of Contents for BR48L series

Page 1: ...om KrowneMetal SELF CONTAINED MODEL SERIES BS36L R __ __ __ __ BS60L R __ __ __ __ __ BS84L R __ __ __ __ __ __ BS108L R __ __ __ __ __ __ __ NS32L R __ __ __ __ NS52L R __ __ __ __ __ NS72L R __ __ _...

Page 2: ...Fax 973 872 1129 sales krowne com www krowne com www facebook com KrowneMetal www twitter com KrowneMetal This equipment is intended for the storage and display of non potentially hazardous bottled or...

Page 3: ...of proper electrical requirements fire flood or natural disaster REPLACEMENT PARTS Must be returned to KMC prepaid Credit will be issued upon return and inspection of defective part LABOR WARRANTY La...

Page 4: ...1 Phase 60Hz We recommend using a dedicated 15 amp circuit minimum Self contained units are supplied with 8 0 grounded cord standard Remote units come with a terminal block inside the box for a hard w...

Page 5: ...steel such as steel wool and chlorine based bleaches The cooler should be cleaned with a mild detergent warm water and a soft cloth All cleaning materials should be washed away and the cooler complete...

Page 6: ...5 150 235 150 235 150 480 140 235 150 235 150 235 150 235 150 H P 1 5 1 4 1 3 1 3 1 5 1 4 1 4 1 3 FULL LOAD AMPS 3 6 6 0 9 0 7 0 3 6 6 0 6 0 9 0 CASE CAPACITY 12 OZ BOTTLES 7 0 15 7 24 5 30 0 5 0 12 0...

Page 7: ...A 134A or 404A 134A or 404A FULL LOAD AMPS 1 0 1 5 2 0 1 0 1 5 2 0 CASE CAPACITY 12 OZ BOTTLES 14 4 21 9 30 0 11 5 17 8 24 7 WINE BOTTLES 750 ML 144 224 302 114 176 248 115V 1 PHASE 60 HZ Krowne Metal...

Page 8: ...DOOR BR and NR SERIES REMOTE 2 3 and 4 DOOR Krowne Metal Corporation 100 Haul Rd Wayne NJ 07470 Toll Free 800 631 0442 Fax 973 872 1129 sales krowne com www krowne com www facebook com KrowneMetal ww...

Page 9: ...Krowne Metal Corporation 100 Haul Rd Wayne NJ 07470 Toll Free 800 631 0442 Fax 973 872 1129 sales krowne com www krowne com www facebook com KrowneMetal www twitter com KrowneMetal 9 PARTS BREAKDOWN...

Page 10: ...BC 555 BC 555 14 Door Gasket BC 552 BC 552 BC 552 BC 552 15 Pilaster 18 BC 542 BC 542 BC 542 BC 542 16 Pilaster Clip BC 543 BC 543 BC 543 BC 543 17A 21 5 8 x 18 Shelf 19 1 2 x 16 BC 648 BC 538 BC 538...

Page 11: ...593 BC 593 BC 593 BC 593 13 Door Handle BC 555 BC 555 BC 555 BC 555 14 Door Gasket BC 693 BC 693 BC 693 BC 693 15 Pilaster 18 BC 542 BC 542 BC 542 BC 542 16 Pilaster Clip BC 543 BC 543 BC 543 BC 543 1...

Page 12: ...C 538 BC 740 BC 740 BC 740 17B 23 5 8 x 18 Shelf 19 5 8 x 18 N A BC 539 BC 539 N A BC 741 BC 741 18 Stainless Steel Evaporator Face Guard 1776 1768 1968 1776 1768 1968 19 Fan Guard BC 516 BC 516 BC 51...

Page 13: ...T RESTRICT AIRFLOW C Check to see if evaporator is frozen If so unit will need to be unplugged to defrost for up to 24 hours D Check interior of unit Make sure evaporator is clear Do not load cooler f...

Page 14: ...K BAR COOLER SLIDE TOP BOTTLE COOLER MUG FROSTER MODEL NO ______________ SERIAL NO ______________ INSTALL DATE _______ NAME OF ESTABLISHMENT ________________________ PHONE NO ______________ ADDRESS __...

Reviews: