Krontek KT160 Rev 4.10
7
Slave [SLA]: This format should be used if you wish to run a KT160 as a slave to another KT160.
Master/Slave operation is achieved by wiring two or more clocks in parallel via the A and B
terminals on the rear of the clock. If the Slave format is not selected the clock will operate as a
Master by default. It is therefore important that all clocks except one be set as Slaves. Having two
Masters on the same circuit will have unpredictable results.
Alpha [ALPH]: This format is compatible with the time string used by used by Adaptive Micro
Systems for their moving message displays.
Syncroline [SLIN]: This is the Krontek Syncroline format.
Net [nET]: This format is compatible with SNTP (Simple Network Time Protocol). The clock will
derive it s time from a network time server. The network interface option must be fitted for this
format to function. See instructions that follow