IV - 13
Maintenance
4.11.2 Changing cutting blades
When replacing observe the cutting
direction right/left and the number of
blades 1 or 2!
•
To remove the cutting blades (1) (only possible
outside in the area of the bow) unscrew the internal
hexagon head screw (2).
•
Push up the collector on the step blade (4) with tyre
lever (3) and first pull the cutting blade down (1) off
the cam and then remove it to the rear.
• Tightening torque of the hexagonal
screw (2) = 85 Nm (8.8)
• Tightening torque of the hexagonal
screw (2) = 110 Nm (10.9)
• Use a high-strength screw locking
agent (for example Loctite).
•
Installation of the new cutting blade (1) in the
reverse order of removal.
4.11.3 Changing dresser segments (right /
left)
•
Release the tension on the connectors (3, 4) on
both sides of the dresser segment (1) by loosening
the screws (2).
•
Unscrew the hexagon head screws with the locking
washers (5) and remove the dresser segments (1).
On assembly observe the tooth
direction of the dresser segments!
Renew the self-locking nuts of the
screw connections (2)!
Absolutely comply with the position of
the carriage bolts (2) and connectors
(3, 4)!
•
Installation of the new dresser segments (1) in the
reverse order of removal.
1
2
2
3
4
5
5
2
1
EC200560