![Krone BiG Pack 870 HDP XC Original Operating Instructions Download Page 225](http://html1.mh-extra.com/html/krone/big-pack-870-hdp-xc/big-pack-870-hdp-xc_original-operating-instructions_2004796225.webp)
Settings
15
Checking/setting Variable Filling System (VFS) 15.20
BiG Pack 870 HDP XC
Original Operating Instructions 150000760_00_en
225
Zero position
.
Turn the flywheel manually in working direction (
) until the roll (4) is
engaged in the zero adjuster (3).
Æ
The Variable Filling System (VFS) is in zero position.
.
The zero position is set correctly if
•
the anvil (14) is lying flush against the set screw (13).
•
the roll centre of the grooved ball bearing (7) rests on the tripping ratchet with dimension
Y=
5 - 8 mm away from the tip of the tripping ratchet (6).
•
the sensing rake (11) has a dimension of
X=
5 - 10 mm to the edge of the packer tray (12).
Check the settings and correct them if required.
Correction
Set the setting screw (13) until the dimension is
Y=
5 - 8 mm between the centre of the
grooved ball bearing and the tripping ratchet tip (6).
Make sure that the grooved ball bearing rets on the tripping ratchet.
Æ
If dimension Y cannot be set, check and set if required the absorbing unit,
Set the threaded rod (9) until the sensing rake (11) has a dimension of
X=
5 - 10 mm to the
edge of the packer tray (12).
15.20.3
Setting the zero adjuster
BP000-235
ü
The Variable Filling System (VFS) is in zero position,
.
ü
The machine is shut down and safeguarded,
.
Release the spring (2).
Loosen the screw (23).
Swing the zero adjuster (3) manually upwards.
Swing the cam disc (5) manually as far as it will go towards (I) and hold it there.
Swing the zero adjuster (3) downwards and turn the eccentric (22) until the roll (4) rests
against the lower area (III) of the zero adjuster.
Tighten the screw (23).
Release the cam disc (5).
ð
The roll (4) of the zero adjuster roll swings in the upper area (II) of the zero adjuster.