Status:
Valid
Version:
1.1
Titel : Operation manual, kronback tracers P12
27/08/2019
Kronback ApS
Filmtorvet 70
Jonstrup
DK-3500 Værløse
Denmark
Fax:(+45) 46 907 910
Page 14 of 20
Menu bottom bar:
At the bottom of the P12 screen the temperature, battery status and battery current
consumption is displayed.
If the P12 is running on battery the current readout is negative. If the battery is being
charged the readout is positive. The current consumption is displayed in mA.
The internal temperature of the P12 is displayed in degrees Celsius
The battery level is presented as a percentage of the full capacity. If the P12 is
charging, the text
Charge
is shown. If the unit is running on battery this text is
changed to
Battery
. The percentage is however always presenting the fuel level of the
battery.
Generator Menu
The generator menu is used for configuring the frequency and level of the tone or tones
that P12 generates.
This menu can be either showing 1 tone, 2 tones, 8 tones (hop) or sweep.
1 Tone
2 Tones
Hop
Sweep
For the tone1 and tone 2 screen a choice between upstream and downstream must be
decided.
For the HOP screen only
upstream
frequencies can be selected.
For the SWEEP screen only
downstream
frequencies can be selected.
Mode: upstream downstream
Max level per tone [dBuV]
104
100
Max level per tone [dBmV]
44
40
Frequency range [MHz]
3-215
60-1220