1.3.6. Ground Terminals
There are two ground terminals: protective ground and electrical earth or
ground from the power supply. They are normally connected by means of a
metal jumper, but they can be isolated one another by eliminating jumper, in
case it is necessary to avoid hum pickups due to the installation.
1.3.7. Remote Control Connectors (RS-485 Interface)
They are located at the rear of the video unit. The connectors, in loop through
configuration, are prepared for connection of the
KROMA
RK-5400 remote
control. These connectors are also useful for to update the futures software
versions.
Configuration:
Terminal 1 - S/C
“ 2 - DATA + (RS485)
“ 3 - RX (RS232)
“ 4 - GND
“ 5 - S/C
“ 6 - TX (RS 232)
“ 7 - DATA - (RS 485)
“ 8 - GND
REM
Figure 1