7
TECHNICAL DATA
50
TT 51 SERIES
www.krohne.com
08/2015 - 4000754203 - MA TT 51 R03 en
7.6 Electrical data for outputs and inputs
In-head transmitter
In-head transmitter
In-head transmitter
In-head transmitter
Intrinsically safe transmitter TT 51 C Ex
Rail-mount transmitter
Rail-mount transmitter
Rail-mount transmitter
Rail-mount transmitter
Intrinsically safe transmitter TT 51 R Ex
Output terminals 6, 7
Input terminals 1, 2, 3, 4, 5
U
i
= V
max
≤
30 VDC
U
0
= U
0C
≤
6.6 VDC
I
i
= I
max
≤
100 mA
I
0
= I
SC
≤
26.4 mA
P
i
= P
max
≤
900 mW
P
0
≤
46 mW
L
i
10
μ
H
L
0
25 mH
C
i
12.1 nF
C
0
583.5 nF
Output terminals 21, 22
Input terminals 1 to 8
U
i
= V
max
≤
30 VDC
U
0
= U
0C
≤
6.6 VDC
I
i
= I
max
≤
100 mA
I
0
= I
SC
≤
28.9 mA
P
i
= P
max
≤
900 mW
P
0
≤
46 mW
L
i
10
μ
H
L
0
25 mH
C
i
12.1 nF
C
0
581 nF