background image

7

4 Mounting

Electronics module • OPTISWITCH 5100 C, 5150 C, 5200 C, 5250 C

30492-EN-210907

Information:

Make sure that the housing is not rotated during the electronics ex-

change. Otherwise the plug may be in a different position later.
9.  Insert the electronics module carefully. Make sure that the plug is 

in the correct position.

10.  Screw in the two holding screws and tighten them
11.  Insert the wire ends into the open terminals according to the wir-

ing plan

12.  Press down the opening levers of the terminals, you will hear the 

terminal spring closing

13.  Check the hold of the wires in the terminals by lightly pulling on 

them

14.  Check cable gland on tightness. The seal ring must completely 

encircle the cable.

15.  Screw the housing lid back on
The electronics exchange is now finished.
As a rule, an exchange of electronics must be documented internally 

if Ex applications are involved.

Summary of Contents for OPTISWITCH 5200C

Page 1: ...Electronics module Handbook Vibrating Level Switch OPTISWITCH 5100 C 5150 C 5200 C 5250 C...

Page 2: ...tructions for Ex areas 4 3 Product description 5 3 1 Configuration 5 3 2 Principle of operation 5 3 3 Packaging transport and storage 5 4 Mounting 6 4 1 Mounting instructions 6 4 2 Mounting preparatio...

Page 3: ...Symbols used Information note tip This symbol indicates helpful additional infor mation and tips for successful work Note This symbol indicates notes to prevent failures malfunctions damage to device...

Page 4: ...e device the required personal protective equipment must always be worn 2 2 Appropriate use The electronics module is a replacement insert for OPTISWITCH 5100 C 5150 C 5200 C 5250 C vibrating level sw...

Page 5: ...ed out in due consideration of the notes on the transport packaging Nonobservance of these instructions can cause damage to the device The delivery must be checked for completeness and possible transi...

Page 6: ...homepage under Downloads 4 3 Installation procedure To exchange the electronics module proceed as follows 1 Switch off voltage supply 2 Unscrew the housing lid 3 Lift the opening levers of the termin...

Page 7: ...two holding screws and tighten them 11 Insert the wire ends into the open terminals according to the wir ing plan 12 Press down the opening levers of the terminals you will hear the terminal spring c...

Page 8: ...signal output e g relay against transistor output The electronics modules of the high temperature version however cannot be exchanged against standard instrument versions If you want to use an electr...

Page 9: ...ctronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907 6 Maintenance 6 1 How to proceed if a repair is necessary If it is necessary to repair the instrument please contact the responsi...

Page 10: ...the electronic modules to be easily separable WEEE directive The instrument does not fall in the scope of the EU WEEE directive Article 2 of this Directive exempts electrical and electronic equipment...

Page 11: ...Supplement Electronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907 8 Supplement 8 1 Technical data Technical data are stated in the operating instructions manual of the respective se...

Page 12: ...Supplement Electronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907 8 2 Trademark All the brands as well as trade and company names used are property of their lawful proprietor origin...

Page 13: ...13 Notes Electronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907...

Page 14: ...14 Notes Electronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907...

Page 15: ...15 Notes Electronics module OPTISWITCH 5100 C 5150 C 5200 C 5250 C 30492 EN 210907...

Page 16: ...process analytics Flow metering monitoring wireless and remote metering solu tions Engineering commissioning calibration maintenance and train ing services Head Office KROHNE Messtechnick GmbH Ludwig...

Reviews: