2.7 General requirements
2.7.1 Vibrations
2.7.2 Magnetic field
INFORMATION!
The following precautions must be taken to ensure reliable installation.
•
Make sure that there is adequate space to the sides.
•
Protect the signal converter from direct sunlight and install a sun shade if necessary.
•
Signal converters installed in control cabinets require adequate cooling, e.g. by fan or heat
exchanger.
•
Do not expose the signal converter to intense vibrations and mechanical shocks. The
measuring devices are tested for a vibration/shock level as described in the chapter
"Technical data" in the manual and the technical documentation.
•
Avoid magnetic field! Keep at least 5 DN distance between electromagnetic flow sensors.
Figure 2-4: Avoid vibrations
Figure 2-5: Avoid magnetic field