DEVICE DESCRIPTION
2
7
DK37/M8 - H250/M8
www.krohne.com
11/2017 - 4002616802 - AD DK37 NEPSI Ex ia R02 en
Type series DK37
Type series DK37
Type series DK37
Type series DK37
The safety description code * consists of the following elements:
* positions which are not needed are omitted (no blank positions)
1
Type series of measuring unit DK
2
Type series of signal converter 37
3
Type series of indicators
M8M - Mechanical indicator
M8E - Electronic indicator
4
Design of indicator housing
without - Indicator housing in PPS
R - Indicator housing in stainless steel
5
Optional differential pressure regulator
RE - Inlet pressure regulator
RA - Outlet pressure regulator
6
Limit switch (M8M version)
K1 - One limit switch
K2 - Two limit switches