KREMLIN
Page 7
Manual : 573.001.212
Whatever the case, when stopping the pump, always leave it filled with material :
For a short duration shutdown, if the flushing has not been carried out, leave the pump
filled with material.
For a long duration shutdown, after flushing the pump, leave it filled with solvent.
SPRAY GUN
Comply with the usual instructions of spray gun servicing (refer to spray gun manual).
FILTER
If the pump is mounted with a filter at the fluid outlet, comply with the usual instructions of filter
servicing (refer to filter manual).
8. SAFETY
DEVICE
AIRMIX
pump : A relief-valve (setting : 6,5 bar / 94 psi) is fitted on the pump air motor - thus protecting
this one from an overpressure which could damage it.
A protection spring, mounted between the air motor and the fluid section, protects the operator during the
pump piston motion.
9. TROUBLESHOOTING
CHART
CAUSE
SOLUTION
The pump does not start.
Check the pump air supply.
Priming trouble :
Be sure that the spray gun is fully opened and air
evacuated through this one.
Î
Air is always coming out from the spray
gun.
Air intake at the fitting or at the suction rod.
Î
When priming, air (or material) does not
come out from the spray gun.
Check the pump valves. If a valve is sticked by dry
paint, it can be unsticked without disassemblying it.
Blow air pressure directly by suction fitting.
The pump does not stop at once when
shutting off the spray gun :
Î
The pump stops only on down stroke
Check exhaust valve or valve seal.
Î
The pump stops only on up stroke.
Check suction valve or upper cartridge.
The pump has stalled, air leakage at the air
motor.
Check air motor valve located under the cover.
Spraying trouble.
Refer to spray gun manual.