Kremlin AIRMIX Instruction Manual Download Page 3

KREMLIN

Page 2

Manual : 573.001.212

Dear Customer,

We thank you very much for purchasing our KREMLIN pump. You are the owner of one of the most
reliable pumping system available on the market.

To make sure your investment will provide full satisfaction, special care has been taken by
KREMLIN during all designing and manufacturing processes.

To obtain the best result, safe and efficient operation of your equipment, we advice you to read and
make yourself familiar with this instruction and service manual. Indeed, the non-compliance with
instructions and precautions stated in this manual could reduce the equipment working life, result in
operating trouble and create unsafe conditions.

1.  EC DECLARATION OF CONFORMITY

The manufacturer :

KREMLIN  REXSON

 with assets of 6 720 000 euros

Head office : 150, avenue de Stalingrad  -  93 245 - STAINS CEDEX - FRANCE
Tel. 33 (0)1 49 40 25 25  - Fax : 33 (0)1 48 26  07 16

Herewith declares that : Pneumatic pump, is in conformity with the provisions of :

EC  - Machinery Directive (Directive 98/37/EC) as amended and with national implementing legislation

Ex  - ATEX Directive (Directive 94/9/EC) : 

 II 2 G (group II, class 2, gas).

Established in Stains, on March 1st 2003,

Daniel TRAGUS
President

2.  GENERAL SAFETY INSTRUCTIONS

WARNING : Any misuse of the equipment or accessories can damage them, result in serious
body injury, fire or explosion hazard and reduce the equipment working life. Read,
understand and comply with the safety instructions hereafter.

The personnel involved in operating and servicing this equipment must be aware of all safety
requirements stated in this manual. The workshop supervisor must be certain that the personnel has
perfectly understood the safety instructions and complies with them.
Read all instruction manuals as well as the tags of the equipments before operating the equipment.
Refer to local safety instructions and comply with them.

„

 

INSTALLATION REQUIREMENTS

Â

 Ground the equipments.

Use the equipment only in a well-ventilated area to prevent from serious body injuries, fire and
explosion hazards. Do not smoke in the spray area.
Never stock paints and solvents in the spray area. Always close the pots and the tins.
Always keep the spray area clean and free from debris (solvent, rags,…).
Read paint and solvent manufacturer's technical instructions.
Spraying of some materials may result in hazardous working conditions. To protect the operator,
respirator mask, hand cream and glasses are required. (Refer to chapter "Safety equipment" of
KREMLIN selection guide).

Summary of Contents for AIRMIX

Page 1: ...RAY PUMP with differential air motor Manual 0309 573 001 212 Date 12 09 03 Supersedes 12 06 03 Modif Tittle KREMLIN REXSON Site de Stains 150 avenue de Stalingrad 93 245 STAINS CEDEX FRANCE Téléphone 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 ...

Page 2: ... EC DECLARATION OF CONFORMITY 2 2 GENERAL SAFETY INSTRUCTIONS 2 3 OPERATING PRINCIPLE 3 4 INSTALLATION 4 5 START UP 5 6 SHUTDOWN AT THE END OF WORK 6 7 MAINTENANCE 6 8 SAFETY DEVICE 7 9 TROUBLESHOOTING CHART 7 The specifications of the pump features and maintenance are available in a documentation enclosed to the manual ...

Page 3: ...n Stains on March 1st 2003 Daniel TRAGUS President 2 GENERAL SAFETY INSTRUCTIONS WARNING Any misuse of the equipment or accessories can damage them result in serious body injury fire or explosion hazard and reduce the equipment working life Read understand and comply with the safety instructions hereafter The personnel involved in operating and servicing this equipment must be aware of all safety ...

Page 4: ...before carrying out any servicing on the gun Never point the spray gun at anyone or at any part of the body MAINTENANCE REQUIREMENTS Â Never modify these equipments Check them daily keep them in a good condition and replace the worn parts only with KREMLIN parts Before cleaning or removing components of the equipment it is compulsory to stop the pump by shutting off the compressed air supply to po...

Page 5: ...E 20 15 Pump model II 2 G II group II 2 class 2 Surface equipment meant to area where explosive atmospheres due to gas vapours mists or air mixtures with dusts will probably appear G gas P prod 120 bar 1741 psi Maximum fluid pressure at the pump outlet P air 6 bar 87 psi Air supply maximum pressure of the pump motor N Serie Serial Nb Number given by KREMLIN REXSON RATIO 20 Pump pressure ratio INST...

Page 6: ...ith KREMLIN T lubricant or with an appropriate cleaning solvent 3 Unscrew the air regulators D and F 4 Interconnect the equipment with the air pressure network clean air P 6 bar 87 psi Install a water drop model 3 8 if it is necessary 5 Connect all the hoses air hose and fluid hose as well as the gun O 6 Remove gun air cap by unscrewing the cap ring FLUSHING WITH SOLVENT 7 Immerse suction rod L in...

Page 7: ...e air cap and spray tip for AIRMIX gun only from the gun and put them into solvent do not put the plastic air cap into solvent 4 Remove suction rod from material container and immerse it in a solvent filled container Take all appropriate precautions in the presence of flammable solvents 5 Point the spray gun towards the material container and trigger the gun When the solvent flows out point the gu...

Page 8: ...tween the air motor and the fluid section protects the operator during the pump piston motion 9 TROUBLESHOOTING CHART CAUSE SOLUTION The pump does not start Check the pump air supply Priming trouble Be sure that the spray gun is fully opened and air evacuated through this one Î Air is always coming out from the spray gun Air intake at the fitting or at the suction rod Î When priming air or materia...