background image

INSTRUCTION MANUAL

AIRMIX 

 PUMP and AIRSPRAY PUMP

with differential air motor

Manual : 0309   573.001.212

Date : 12/09/03 – Supersedes : 12/06/03

Modif. Tittle

KREMLIN  REXSON

  –  Site de Stains : 150, avenue de Stalingrad

93 245 - STAINS CEDEX - FRANCE

Téléphone : 33 (0)1 49 40 25 25       Fax : 33 (0)1 48 26 07 16

Summary of Contents for AIRMIX

Page 1: ...RAY PUMP with differential air motor Manual 0309 573 001 212 Date 12 09 03 Supersedes 12 06 03 Modif Tittle KREMLIN REXSON Site de Stains 150 avenue de Stalingrad 93 245 STAINS CEDEX FRANCE Téléphone 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 ...

Page 2: ... EC DECLARATION OF CONFORMITY 2 2 GENERAL SAFETY INSTRUCTIONS 2 3 OPERATING PRINCIPLE 3 4 INSTALLATION 4 5 START UP 5 6 SHUTDOWN AT THE END OF WORK 6 7 MAINTENANCE 6 8 SAFETY DEVICE 7 9 TROUBLESHOOTING CHART 7 The specifications of the pump features and maintenance are available in a documentation enclosed to the manual ...

Page 3: ...n Stains on March 1st 2003 Daniel TRAGUS President 2 GENERAL SAFETY INSTRUCTIONS WARNING Any misuse of the equipment or accessories can damage them result in serious body injury fire or explosion hazard and reduce the equipment working life Read understand and comply with the safety instructions hereafter The personnel involved in operating and servicing this equipment must be aware of all safety ...

Page 4: ...before carrying out any servicing on the gun Never point the spray gun at anyone or at any part of the body MAINTENANCE REQUIREMENTS Â Never modify these equipments Check them daily keep them in a good condition and replace the worn parts only with KREMLIN parts Before cleaning or removing components of the equipment it is compulsory to stop the pump by shutting off the compressed air supply to po...

Page 5: ...E 20 15 Pump model II 2 G II group II 2 class 2 Surface equipment meant to area where explosive atmospheres due to gas vapours mists or air mixtures with dusts will probably appear G gas P prod 120 bar 1741 psi Maximum fluid pressure at the pump outlet P air 6 bar 87 psi Air supply maximum pressure of the pump motor N Serie Serial Nb Number given by KREMLIN REXSON RATIO 20 Pump pressure ratio INST...

Page 6: ...ith KREMLIN T lubricant or with an appropriate cleaning solvent 3 Unscrew the air regulators D and F 4 Interconnect the equipment with the air pressure network clean air P 6 bar 87 psi Install a water drop model 3 8 if it is necessary 5 Connect all the hoses air hose and fluid hose as well as the gun O 6 Remove gun air cap by unscrewing the cap ring FLUSHING WITH SOLVENT 7 Immerse suction rod L in...

Page 7: ...e air cap and spray tip for AIRMIX gun only from the gun and put them into solvent do not put the plastic air cap into solvent 4 Remove suction rod from material container and immerse it in a solvent filled container Take all appropriate precautions in the presence of flammable solvents 5 Point the spray gun towards the material container and trigger the gun When the solvent flows out point the gu...

Page 8: ...tween the air motor and the fluid section protects the operator during the pump piston motion 9 TROUBLESHOOTING CHART CAUSE SOLUTION The pump does not start Check the pump air supply Priming trouble Be sure that the spray gun is fully opened and air evacuated through this one Î Air is always coming out from the spray gun Air intake at the fitting or at the suction rod Î When priming air or materia...