CAUTION :
Before any action on the pump, shut off the compressed air supply and
depressurize the system.
The pump is manufactured under the ATEX agreement and can not be modified.
KREMLIN REXSON will not be held responsible for any failure to comply with that instruction.
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
FLUID MOTOR OR AIR MOTOR REPLACEMENT (REFER TO DOC. 573.176.050)
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
Disassemble all the accessories of the pump.
Disassemble the pump from the bracket by removing the nuts that hold on the U-bolts.
Put aside the pump (the pump is fitted with an hoisting ring).
To replace the fluid section (2) or the air motor (1), the pump must be removed (see bellows) :
-
Remove the FLUID SECTION (refer to Doc. 573.175.050)
Disassemble the connecting rod (41), the suction valve (30), the cylinder (21).
Remove the 3 nuts (11) that hold on the 3 tie-rods (7) and slide the upper flange (1). Hold on the
guide rod of the air motor and unscrew the piston (22).
-
Remove the COUPLING part.
-
Remove the air motor.
DISASSEMBLY / REASSEMBLY OF THE FLUID SECTION
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
Unscrew the fitting (38) and the screws (43 and 45) to remove the attachment fluid tube (41).