SUCTION VALVE (REFER TO DOC. 573.032.050)
Unscrew the suction valve (5) by holding cylinder (2).
The ball (10) is secured on the valve (5) by means of a circlips (9).
Clean the parts.
Reinstall the suction valve and the seal (25). Replace them if necessary.
EXHAUST VALVE
Unscrew cylinder (2) and pull it downwards.
Unscrew exhaust valve (6) by holding piston (3).
Remove ball (15).
Clean the parts and reinstall them. Be certain seal (8) is installed. Replace the parts if necessary.
LOWER MOBILE PACKING
Unscrew cylinder (2) and pull it downwards.
Unscrew stuffing-box (7) to release GT seal (13) from exhaust valve (6).
Remount the parts in reverse order.
For that :
-
Install the GT seal onto exhaust valve (6).
-
Screw stuffing-box (7).
-
The seal must be blocked by screwing mobile stuffing-box (7) onto exhaust valve (6).
If necessary replace seal (8) when reinstalling cylinder (2).