background image

KREMLIN REXSON

- 1 -

N° : 578.164.110-UK-1204

CAUTION :

Before any action on the pump, shut off the compressed air supply and
depressurize the system.

The pump is manufactured under the ATEX agreement and can not be modified.

KREMLIN REXSON will not be held responsible for any failure to comply with that instruction.

Guards (air motor cover, coupling shields, housings …) have been designed for

safe use of the equipment.

The manufacturer will not be held responsible for bodily injury or failure and / or

damage to property due to removal or partial removal of the guards

SUCTION VALVE (REFER TO DOC. 573.080.050)

Unscrew suction valve (5) by holding cylinder (2).

The ball (10) is secured on the valve (5) by means of a circlips (9).

Clean the parts.

Reinstall suction valve (5) and seal (25). Replace them if necessary.

EXHAUST VALVE AND MOBILE PACKING

Unscrew cylinder (2) and pull it downwards.

Unscrew exhaust valve (6) by holding piston (3).

Remove ball (17), washer (12) and GT seal (13).

Clean the parts.

Remount the parts in reverse order.

For that :

Install GT seal (13), washer (12) and ball (17) onto exhaust valve (6).

Screw exhaust valve (6) into the piston. The seal must be blocked by screwing exhaust valve (6)

strongly.

If necessary, replace seal (8) when reinstalling cylinder (2).

Summary of Contents for AIRMIX Series

Page 1: ...sembly and start up please read and clearly understand all the documents relating to this equipment professional use only THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Page 2: ... to removal or partial removal of the guards SUCTION VALVE REFER TO DOC 573 080 050 Unscrew suction valve 5 by holding cylinder 2 The ball 10 is secured on the valve 5 by means of a circlips 9 Clean the parts Reinstall suction valve 5 and seal 25 Replace them if necessary EXHAUST VALVE AND MOBILE PACKING Unscrew cylinder 2 and pull it downwards Unscrew exhaust valve 6 by holding piston 3 Remove ba...

Page 3: ...g REVERSING BLOCK REFER TO DOC 573 045 050 Guards air motor cover coupling shields housings have been designed for safe use of the equipment The manufacturer will not be held responsible for bodily injury or failure and or damage to property due to removal or partial removal of the guards Disassemble cover 32 by removing CHc screws 33 Dissociate female yoke 12 from reversing block lever 9 Dismount...

Page 4: ... 6 8 2 25 9 10 26 5 24 23 1 3 A 2 A 1 A 1 A 2 A 2 A 1 A 1 A 2 A 1 C 1 A 1 A 1 Index Instruction Description Part number PTFE grease TECHNILUB grease 10 ml 560 440 101 Graphite grease Graphite grease box 1 kg 2 204 lb 560 420 005 Medium strength Aneorobic Pipe sealant Loctite 577 A2 A1 C1 ...