KREMLIN REXSON
- 1 -
N° : 578.164.110-UK-1204
CAUTION :
Before any action on the pump, shut off the compressed air supply and
depressurize the system.
The pump is manufactured under the ATEX agreement and can not be modified.
KREMLIN REXSON will not be held responsible for any failure to comply with that instruction.
Guards (air motor cover, coupling shields, housings …) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
SUCTION VALVE (REFER TO DOC. 573.080.050)
Unscrew suction valve (5) by holding cylinder (2).
The ball (10) is secured on the valve (5) by means of a circlips (9).
Clean the parts.
Reinstall suction valve (5) and seal (25). Replace them if necessary.
EXHAUST VALVE AND MOBILE PACKING
Unscrew cylinder (2) and pull it downwards.
Unscrew exhaust valve (6) by holding piston (3).
Remove ball (17), washer (12) and GT seal (13).
Clean the parts.
Remount the parts in reverse order.
For that :
Install GT seal (13), washer (12) and ball (17) onto exhaust valve (6).
Screw exhaust valve (6) into the piston. The seal must be blocked by screwing exhaust valve (6)
strongly.
If necessary, replace seal (8) when reinstalling cylinder (2).